What Makes Steel Manhole Covers Unsafe?

When it comes to steel manhole covers, reinforcement may be more of a hinderance than a help, claims petroleum consultant James E. Young. And he puts some covers to the test to prove it.

US and European Standards differ...

What could cause steel manhole covers to be unsafe? There are two critical overriding design issues related to the safe use of steel manhole covers in petroleum applications:

1. Strength: Stresses resulting from vehicle traffic loading should not exceed the ultimate strength of the steel cover’s thickness at the diameter being tested.

2. Flatness: Every time that the loading weight of a vehicle exceeds the cover’s strength, the steel material yields. This causes the center of the cover to become permanently “dished.” Every instance of overloading results in the cover becoming less and less flat, which, as explained later in this article, makes the cover unsafe once the steel has been yielded a number of times.

Diamond-plated material
Steel manhole covers in the petroleum industry have been manufactured for decades using a material called 4-Way Floor Plate. It has a raised diamond pattern on the surface and is sometimes referred to as “diamond plate” or “tread plate.” Inland Steel developed this product originally for use on walkways, catwalks, stairways outdoors and various warehouse applications. It has also been adapted for use in manhole cover installations in service stations, petroleum fuel depots and other private transportation areas such as shopping centers, convenience stores and similar gasoline dispensing facilities.

Today, that same floor plate product is manufactured by Nucor and Lukens in the US and many overseas mills in addition to Inland Steel. Because steel has specific tensile and yield-strength properties and floor plate has common manufacturing standards, it should not matter where the plate material is made. Under the same loading conditions, the cover material itself should have the same performance standards for equal diameters and thicknesses regardless of which mill’s floor plate is used.

Comparing US and European standards
The most widely accepted criterion for highway traffic loading situations in the United States can be read in Standards Specifications for Highway Bridges, which is published by the American Association of State Highway and Transportation Officials (AASHTO). That publication refers to United States Federal Specification RR-F-621 (frames, covers, gratings, steps, sumps and catch basin manholes).

These federal specifications taken together define loading compliance for the H20 (two axle truck) and HS20 (tractor truck with a tandem axle semi-trailer) and just how to determine if compliance has been met. The maximum legal axle load on highways in the US is 32,000 pounds, or 16,000 pounds for each set of dual tire wheels. That means each manhole cover, by design, must be prepared to withstand up to 16,000 pounds of loading. Since there is no allowance for any permanent center deflection from such loading, none is permitted.

Overseas, another and different standard is applied for manhole cover loading requirements. It is the European Standard 124:1994 (gully tops and manhole tops for vehicular and pedestrian areas—design requirements, type testing, marking, quality control). The testing section of that Standard calls for various maximum loading requirements, depending on the specific application. There are six classes from which to choose the loading requirement, and selection of the appropriate class is the responsibility of the designer. According to European officials, B125 is the classification for manhole covers in the petroleum equipment industry under the international standard.

Class B125 calls for a maximum test loading of 18,827 pounds, five different times for 30-second intervals each. After each loading, the permanent deflection of the geometric center of the manhole cover is to be measured. The European Standard limits acceptable permanent center deflection to 1/100 of the cover diameter, or the lid must be replaced for safety’s sake.

From a design guidance perspective, the European Standard gives design criteria and guidelines to the manhole cover manufacturer to determine when a manhole cover is no longer in a safe condition. The Standard also clearly differentiates among loading requirements, depending on the application. For example, in airport runway manhole applications, the loading limits are substantially higher than the 18,827 pounds required for the petroleum industry applications addressed in this article.

The European Standard recognizes that manhole covers are manufacturered using various materials. Furthermore, the Standard also recognizes that steel manhole covers generally do not fracture or fail when overloaded, but instead yield and become permanently deformed, thus leading to an unsafe condition. For the US standard, however, manhole covers must withstand 16,000 pounds of loading and demonstrate no resulting permanent center deflection. The “zero” allowable permanent center deflection requirement in the US standard stems from the assumption that all manhole covers are cast iron and will either crack or fail rather than yield.

When a steel manhole cover “rattles” and “rocks” in its skirt rim assembly and is driven over, a condition exists in which the cover can flip up. If the outside edges stick up above ground level because the center of the cover is so permanently “dished,” the cover is unsafe. By limiting total permanent center deflection to no more than 1/100 of the diameter, neither of these unsafe conditions will occur. These conditions become the defining issues from a safety standpoint.

Load rating testing
Anecdotal evidence from field inspections, petroleum distributors, service station operators, contractor comments and litigation confirms that a substantial number of steel manhole covers in the field need to be replaced. Nevertheless, I have not been able to find any published test results on outside testing work on load ratings issues by any manufacturer of steel manhole covers manufactured for petroleum applications other than a collaborative research project in which I participated when I was president of Ramco of Indiana. (See “Load Rating Analysis for Steel Manhole Covers,” Petroleum Marketer, Sep/Oct, pp 24, 62.)

The results and conclusions of that collaborative project are incorporated in this article. In our research on manhole covers, we determined the theoretical steel manhole cover design thicknesses required to meet US load rating standards for every cover diameter. The table above provides the information necessary to assure that a manhole cover can be designed for any diameter to withstand a specific loading limit, without yielding unsafely, by using the material thickness required.

In this latest research effort, I selected four leading US manhole cover manufacturers and, through normal purchasing channels, randomly obtained one 36-inch diameter steel manhole cover from each of the four companies for load rating testing. An outside independent laboratory conducted all testing to assure independently recorded data, and I was present to observe. Testing was conducted by Thomas J. Enneking, PhD, and Chairman of the Civil Engineering Department at Tri-State University, Angola, Indiana.

Information and data were collected according to the following test protocol:

1. Prior to load rating testing, each cover was surveyed to determine its initial flatness, thickness and the method used for any reinforcement.

2. Test loads were applied at seven different load weights from 10,000 to 30,000 pounds for 30 seconds at each weight.

3. Center deflection (see diagram) was measured at each loading weight level while the cover was under load and after loading was released.

4. Each cover was inspected to determine any visual damage—particularly in terms of lack of flatness—and placed back into its respective skirt assembly during the testing process to determine how the cover’s condition and permanent dishing affected safety performance.

Diagramm A - Testing Method

 

Diagram B - Installation Guedeline for Safety
   
   
   
Table 1—Limit Analytical Load in Pounds for 36,000 psi Maximum Stress in Hot-Rolled Steel
Steel Floorplate Diameters
Material
Thickness
Inches
18"20"24"30"36"38"42"48"
3/16"123218503563341183410311129902708
1/4"1837612682840261425086463944604038
5/16"25638176931172285697096647262225634
3/8"341052353715593113999440861082777495
7/16"437793021320016146331211711052106259621
1/2"5465837721249901826915129137981326512012
9/16"6674446062305162230918474168501619914668
5/8"8003655235365932675122153202051942417589
3/4"11023976079504023684630513278302675524226
7/8"145267100252664174855440208366733525631923
1"185119127755846376187451239467334492840681

Deflecting test results
All tested manhole covers were 36 inches in diameter. Three of the four manufacturers (Companies B, C and D in Table 2) utilized K-inch-thick floor plate material and reinforcement techniques. Two of those three used 3/16-inch-thick steel channel for reinforcement, while the third used 3/16-inch thick steel flat stock. The fourth manufacturer (Company A) used H-inch-thick floor plate material with no reinforcement.

All four manufacturers claimed in product literature that these manhole products met US load rating requirements. Diagram A on this page explains the “Load” and “No load” deflection measurements taken. The test results are shown in Table 2. The results shown in Table 2 confirmed what was shown in Table 1 (developed in 1995) from a theoretical perspective: the actual load rating a steel manhole cover will support is more a function of the cover’s actual thickness and diameter—not how or if the cover is reinforced.

Cover A met the European load rating standard; it is H-inch-thick with no reinforcement. At 17,500 pounds of center loading, Cover A incurred 0.29 inches of permanent center deflection; if the data were interpolated, the permanent center deflection would be 0.36 inches with a center loading test of 18,827 pounds. None of the K-inch-thick reinforced covers met either the US or European load rating requirement. At 17,500 pounds of center loading, for example, the H-inch-thick cover incurred 0.29 inches of permanent center deflection while the three K-inch-thick reinforced covers incurred permanent center deflection of 0.45 to 0.79 inches. The latter permanent center deflections are well above the maximum 0.36 inches European standard requirement for a 36-inch-diameter steel manhole cover.

Actual testing results show that limiting deflection to 1/100 of the diameter (0.36 inches for the covers tested) is a good standard for determining safety guidelines. Still, the US standards do not allow for any permanent center deflection resulting from any amount of loading—and, if applied strictly, none of the four covers complied.

In fact, it would take a L-inch-thick steel cover, as a minimum, to meet US standards. However, the US standards were written around highway traffic requirements that assumed all manhole covers were cast iron—not steel. Since a cast iron cover with permanent center deflection probably had to fracture to do so, “zero deflection” is probably a reasonable requirement for cast iron covers. On the other hand, the European standard takes into consideration that manhole covers can be made out of steel. This standard provides for an acceptable amount of permanent center deflection, since steel covers can tolerate some permanent deflection and still safely meet loading requirements.

Table 2—Deflection Measurements in Inches
Loading Weight (lbs.)Company A 1/2-inch coverCompany B 3/8-inch coverCompany C 3/8-inch coverCompany D 3/8-inch cover
10,000    
Load
No load
0.65
0.03
0.61
0.18
0.55
0.10
0.49
0.14
12,500    
Load
No load
0.76
0.05
0.79
0.26
0.73
0.18
0.63
0.21
15,000    
Load
No load
0.92
0.16
0.94
0.33
0.96
0.31
0.80
0.33
17,500    
Load
No load
1.05
0.29
1.31
0.79
1.44
0.70
0.95
0.45
20,000    
Load
No load
1.17
0.43
1.36
0.79
1.64
0.91
1.09
0.55
24,000    
Load
No load
1.29
0.50
1.41
0.79
(See Note) (See Note)1.26
0.67
30,000    
Load
No load
1.52
0.86
1.50
0.79
(See Note) (See Note)1.49
0.85
 
Note: Company C reinforcement welds first started breaking at 12,500 pounds; they broke again at 17,500 and could not be tested above 20,000 because of reinforcement failure.

After loading performance
Another important finding in this latest research resulted from putting the four covers back into their respective skirt assemblies during testing. This was done to focus on the safety issues of manhole covers after loading. The 1/2-inch-thick cover that was not reinforced yielded symmetrically and did not “rock” or “rattle” in its skirt rim even after 30,000 pounds of loading. However, all three reinforced 3/8-inch-thick covers yielded non-symmetrically and “rocked” unsafely when placed back into their respective skirt assemblies. In each of the three latter cases, this occurred before 16,000 pounds of loading was reached because the cover had become so “out of flat,” it could “flip up” if driven over in a certain way.

The second safety issue focused on whether the outside edge lines of the covers were above grade level due to the amount of total permanent center deflection from all the load rating testing. Any manhole cover installed at grade level with permanent center deflection exceeding 1/100 of the cover’s diameter is likely to be unsafe because the outside edge of the cover rises above grade level as shown in Diagram B above.

The H-inch-thick steel cover remained in the safe condition in both respects until loading exceeded 18,827 pounds—within the loading requirements of both the US and European standards. The three K-inch-thick steel covers all had their outside edges above grade level before 16,000 pounds of loading was reached.

36 inch Manhole cover installed

Lessons learned
These test results help explain why so many of the larger steel manhole covers already installed in petroleum re-fueling locations rock and rattle unsafely in their skirt assemblies when vehicles drive over them. The primary cause is an under-designed cover that is too thin, whether or not it has reinforcement. In these situations, the solution is simple: replace each unsafe steel manhole cover with one that is properly engineered.

The correct non-reinforced thickness for a steel round manhole cover of any diameter can easily be determined by using the theoretical load rating chart (See Table 1 on page 29). The chart tells the reader what the cover thickness should be for each manhole cover diameter and load rating requirement desired. If a properly designed cover subsequently yields and becomes unsafe, it means that loading has occurred above design limits a sufficient number of times to cause the problem.

Unintended consequences are a key finding in this latest test. Reinforcement of the three K-inch-thick manhole covers tested caused two unintended consequences. Two of the three reinforced manhole covers were “out of flat” before starting any testing; they came from the manufacturers that way. The cause appeared to be distortion from the heat and from the stress of welding reinforcement material to the covers.

More importantly, all three covers then yielded non-symmetrically as loading was applied. As a result, all three K-inch-thick reinforced covers rocked unsafely prior to reaching 16,000 pounds of loading, rather than fulfill the manufacturers’ intent of strengthening the covers through reinforcement to meet the 16,000 pound US loading requirement.

How did we end up in the situation we find ourselves in today? US standards require that every manhole cover subject to vehicle traffic withstand 16,000 pounds of loading with no permanent center deflection. The European standard recognizes that some amount of permanent center deflection can be permissible and still result in a safe steel manhole cover.

The testing results in this article indicate that a number of US manhole cover manufacturers have not applied consistent design principles that enable them to come close to meeting either US or European load rating standards for their steel manhole covers. Reduced manufacturing costs allow manufacturers to sell these K-inch-thick reinforced covers for up to 10 to 15 percent less than H-inch-thick steel covers with no reinforcement.

Savings are illusionary here, however, if safety is an issue. Manhole covers correctly engineered never need to be replaced for safety reasons unless they have actually incurred loading above legal limits several times.

Steel is a very predictable material from a perspective of behavior and strength. That’s why load rating safety can be simply a function of the manhole cover’s diameter and thickness.

Reinforcement of covers creates an additional problem because these covers not only yield with lighter loads, they yield non-symmetrically. This reinforcement design approach is flawed as it further contributes to an unsafe condition as loading approaches legal limits due to non-symmetrical yielding.

To ensure no unintended consequences, the best approach is to install steel manhole covers that are manufactured with the proper floor plate thickness and no reinforcement.

If manufacturers use the theoretical design chart included in this article to determine the steel manhole cover thickness required for any diameter, they will produce a product that even meets the higher European standard weight requirement. The manhole produced will have an acceptable permanent center deflection. And the end result will be a product that is safe.

 

Jim Young provides consulting services to the petroleum industry